- Operate BTS channels in a batch
In USEFUL DOCS
Operate BTS channels in a batch Some customers asked us how to operate BTS channels together, such as how to start up tests together and how to export data all together. In fact, it’s easy. […]
- how to set up CVC test without current end condition?
In USEFUL DOCS
how to set up CVC test without current end condition? For regular battery constant current charge tests,when you use constant voltage to charge the battery, the current flows into the battery becomes […]
- Problems in Estimating Battery Lifetimes
In USEFUL DOCS
Problems in Estimating Battery Lifetimes Determining battery lifetimes is beset with difficulties. Performance data are not generally available and costly to generate since large numbers of batteries […]
- How to find out the mid machine and tester ID
In USEFUL DOCS
How to find out the mid machine and tester ID Sometime when you have trouble in using Neware BTS, the technicans from Neware may ask you the mid machine or the tester device ID, do you know how to […]
- How to export BTS data to txt or xls format for further use?
In USEFUL DOCS
Most customers know that BTSDA software is designed for the NDA file format, but can we write to another format such as .CSV or .txt? The answer is definitely YES. Please refer to the following […]
- Get more than 100% capacity from a cell?
In USEFUL DOCS
Get more than 100% capacity from a cell? Generally, the capacity comes out from a battery(discharge capacity) will be less than the capacity comes into a battery(charge capacity). But for some […]
- DCIR test operation in BTSDA
In USEFUL DOCS
DCIR test operation in BTSDA DCIR is a key parameter to the battery performance. To calculate DCIR, there should be 2 voltage values and 2 current values. DCIR or d.c. resistance is another key […]
- Easiest way to get the information of Neware BTS middle machine
In USEFUL DOCS
Easiest way to get the information of Neware BTS middle machine When new customers try to connect Neware battery testers with their computer, the 1st question is how to tell the status of middle […]
- BTSDA only shows sectional battery test data?
In USEFUL DOCS
BTSDA only shows sectional battery test data? A question about BTSDA comes from one of our customers. I am using BTS TestControl 5.3.0013 (2010.6.2) with an 8 channel battery tester, model […]
- Connect battery testers to computer
In USEFUL DOCS
Connect battery testers to computer For mostly customers, before you are excited to start up a test, the 1st thing you are supposed to do is connect the tester to your computer, right? If you are new […]
- how to set up different record interval for each step?
In USEFUL DOCS
how to set up different record interval for each step? This is a question from one of our BTS4000 customers. We found it very useful in our development to run a pulse charging regime. For example we […]
- NDA to CSV or XLS conversion
In USEFUL DOCS
NDA to CSV or XLS conversion Question: We have some Neware battery cyclers that we would like to integrate in our automated data processing system. Is there a way to automatically convert or save the […]
- Careful using 0.1s or 1s data sampling interval for battery life cycle tests
In USEFUL DOCS
Careful using 0.1s or 1s data sampling interval for battery life cycle tests For Neware BTS4000 client software, the default sampling time interval is 0.1s, which means the testing data will be […]
- COM port errors and bugs of old version BTSDA
In USEFUL DOCS
COM port errors and bugs of old version BTSDA For some BTS3000 COM port edition battery testers customers, they may meet COM port errors sometimes. And for customers who are using TC5.3 software, […]
- Can Neware BTS software be used for cell grouping or grading
In USEFUL DOCS
Can Neware BTS software be used for cell grouping or grading Some customers asked us about the cell grouping or grading of Neware BTS software. Is it possible for the Neware BTS software be used for […]
- Report generator in BTSDA
In USEFUL DOCS
Report generator in BTSDA After you open a NDA file with BTSDA, then you can export the file to the format you want such as excel, pdf, txt. And you can generate and customize the report. Right click […]
- How to set up high frequency test script correctly?
In USEFUL DOCS
How to set up high frequency test script correctly? For some customer, they’d like to use BTS4000 for high frequency(such as 500ms), so they’d set up a testing script likes the following […]
- Change views in BTS software client
In USEFUL DOCS
Change views in BTS software client By clicking the buttons in the following pictures, you can switch different views in Neware BTS software client. […]
- Low Dependence on PC
In USEFUL DOCS
Low Dependence on PC Comparing with some battery testing systems in the market, there’s another amazing characteristic of Neware battery tests – low dependence on PC. When running the […]
- How to migrate BTS database to a new computer
In USEFUL DOCS
How to migrate BTS database to a new computer For some customers, they’d like to keep all the BTS testing history data in their computers, but as time goes by, the data size becomes larger and […]
- Connect to BTS9000
In USEFUL DOCS
Connect to BTS9000 Before you get started, first of all, you are supposed to connect BTS9000 with your host computer, right? Let’s do it. The main window of the BTS9000 client software looks like the […]
- Rechargeable Batteries — compared and explained in detail
In USEFUL DOCS
Rechargeable Batteries — compared and explained in detail NiMH (Nickel-Metal Hydride) — A good choice for a chargeable battery Pros: Rechargeable Works great in high-drain devices Much larger […]
- Easy connection way with Neware BTS 4000 Series Battery Testing System!
In USEFUL DOCS
Here are the “Easy connection way with Neware BTS 4000 Series Battery Testing System” Steps. 1, Connecting Connect tester with network cable via RS485 COM Port, and connect mid-machine to […]
- What does the △V stand for and its application?
In USEFUL DOCS
For NiMH battery, there will be a voltage drop when battery gets fully charged. This drop rates you can specify as a cut-off condition for the charge step. -△V is enabled only for CC charge step. […]
- How to get the battery capacity density in BTS software
In USEFUL DOCS
For many customers who are doing battery material research, it’s important fro them to get the ‘capacity density’ of the battery. Some customers don’t know by using our […]
- Connect BTS3000(COM port) to Computer
In USEFUL DOCS
Connect BTS3000(COM port) to Computer Connect BTS3000(COM port) to Computer 1. The network cable connect with any of the COM port of the tester, please refer to the following picture. Maybe you are […]
- How to deal with DB Connection Failed when using BTS software
In USEFUL DOCS
How to deal with DB Connection Failed when using BTS software Here is a case from one of our customers. Let’s see his question first. I recently purchased 24 Neware BTS channels (16 5V1A, 8 […]